Home/Racine/Specialty Thermometer Calibration
Grouped Discipline

Specialty Thermometer Calibration in Racine

ISO/IEC 17025 accredited calibration for 4 related instruments — covering Liquid-in-Glass Thermometer / Glass Thermometer, Bimetal Thermometer / Dial Thermometer, Pyrometer, and more. NIST-traceable results with documented uncertainty throughout the Racine service area.

StandardISO/IEC 17025
TraceabilityNIST
Scope4 Variants
4 Grouped
ISO 17025
NIST Traceable
5D Turnaround
Overview

About Specialty Thermometer Calibration

DOC REF: TCS-GRP-SPE

Specialty Thermometer Calibration in Racine encompasses a family of related equipment calibrated under a shared accredited methodology. Each instrument category below is served with NIST-traceable reference standards, documented measurement uncertainty, and certificates issued under an ISO/IEC 17025 accredited quality management system.

Because these instruments share calibration methodology — including thermal stabilization, reference thermometer placement, and uncertainty analysis — they are consolidated on a single service page. Each subsection below details the specific instrument variant, and a dedicated quote can still be requested for any single item or a mixed manifest spanning the group.

Equipment Covered

Instruments in This Group

DOC REF: TCS-GRP-COV

Liquid-in-Glass Thermometer / Glass Thermometer Calibration

Liquid-in-glass thermometer calibration is the process of verifying and documenting the accuracy of glass thermometers that rely on the thermal expansion of a liquid column—such as mercury, spirit (alcohol), or galinstan—to indicate temperature. Calibration is performed by comparing the thermometer under test against a standard platinum resistance thermometer (SPRT) calibrated on the International Temperature Scale of 1990 (ITS-90), or by verification at known fixed points such as the ice point (0 °C) and the gallium melting point (29.7646 °C).

  • ASTM Liquid-In-Glass Thermometer Calibration
  • Total Immersion Thermometer Calibration
  • Partial Immersion Thermometer Calibration
  • Mercury-In-Glass Thermometer Calibration

Bimetal Thermometer / Dial Thermometer Calibration

Bimetal thermometer and dial thermometer calibration is the process of verifying and adjusting a mechanical temperature instrument so that its readings align with a known reference standard traceable to NIST and the International Temperature Scale of 1990 (ITS-90). Bimetallic thermometers use a helical element composed of two bonded metals with different coefficients of thermal expansion.

  • Gas-Actuated Dial Thermometer Calibration
  • Capillary Dial Thermometer (Remote Reading) Calibration
  • Sanitary (CIP) Bimetal Thermometer Calibration

Pyrometer Calibration

Pyrometer calibration is the process of verifying and documenting the measurement accuracy of a non-contact radiation thermometer against a known reference standard. Pyrometers determine temperature by detecting the intensity of thermal radiation emitted by a target object and converting that energy into a temperature reading using Planck's radiation law or the Stefan-Boltzmann relationship.

  • Optical (Disappearing-Filament) Pyrometer Calibration
  • Spot Infrared Pyrometer Calibration
  • Ratio (Two-Color) Pyrometer Calibration
  • Fixed (Process) Pyrometer Calibration

Thermal Imaging Camera Calibration

Thermal imaging camera calibration is the process of verifying and documenting the radiometric accuracy of an infrared imaging system against known reference standards. Thermal cameras detect infrared radiation emitted by surfaces and produce a two-dimensional temperature map across their detector array.

  • Handheld Thermal Imaging Camera Calibration
  • Fixed-Mount Thermal Imaging Camera Calibration
Local Context

Calibration Demand in Racine

DOC REF: TCS-GRP-GEO

Temperature Calibration Demand in Racine, WI

Racine, WI is home to more than 300 established manufacturing firms across Racine County, creating substantial demand for temperature calibration services. Modine Manufacturing, headquartered on De Koven Avenue, designs and produces thermal management systems including heat exchangers, coils, and cooling components for vehicular, industrial, and commercial HVAC markets. Precise temperature measurement is fundamental to Modine's product validation testing, which is conducted at the company's state-of-the-art facility in Wisconsin. S.C. Johnson & Son, the global chemical specialty manufacturer headquartered in Racine, relies on temperature-controlled processes for formulating home care and personal care products. Additional manufacturers such as InSinkErator, Twin Disc, and Case IH maintain production operations where thermal process control directly affects product quality and regulatory compliance.

Local Compliance Requirements

Manufacturing facilities in Racine are subject to overlapping federal, state, and industry-specific temperature calibration requirements:

  • The Wisconsin Department of Agriculture, Trade and Consumer Protection (DATCP) enforces the Wisconsin Food Code, adopted from the 2013 FDA Food Code, which mandates time and temperature control for safety foods throughout processing, storage, and distribution.
  • FDA 21 CFR Part 117 requires food processing operations to maintain calibrated temperature monitoring instruments as part of preventive controls and Hazard Analysis programs.
  • OSHA 29 CFR 1910 standards govern workplace environments where thermal hazards are present, requiring verified temperature instrumentation in chemical manufacturing and industrial heat treatment operations.
  • ISO/IEC 17025 accreditation is recognized across Racine County's advanced manufacturing sector as the benchmark for calibration laboratory competence, ensuring measurement results are NIST-traceable and internationally accepted.

Calibration intervals and documentation requirements are determined by the applicable regulatory framework, with certificates issued to support audit readiness and continuous compliance.

01
Group
Specialty Thermometer Calibration
02
Variants
4 instruments
03
Location
Racine
04
Accreditation
ISO/IEC 17025 · A2LA
Related Services

Other Calibration in Racine

DOC REF: TCS-GRP-XREF